Bacteriological Incubator

Service Overview

Model Number : NI-AUV
HSN CODE : 84192010

  • Vertical Autoclave widely used in Microbiology, Medicine, Waste treatment, Pharma QC / QA / R & D and all applications requiring sterilization.
  • Double walled construction with Inner chamber (boiler) made of Stainless Steel 16 SWG sheet – 304 grade and Outer shell of Stainless-Steel sheet – 304 grade, mirror polish.
  • The Boiler and outer shell is provided with air insulation.
  • Lid is made of die pressed Thick Stainless-Steel plate & is equipped with Pressure gauge, Steam release/Exhaust valve & spring-loaded safety valves & ¼” BSP Port fitted with coupling for validation purpose.
  • Foot lifting arrangement for the lid.
  • Fully Argon welded to avoid steam and pressure leakage.
  • Heavy duty industrial flange heaters.
  • Full sterilization cycle including Air purging, Sterilizing hold time, Cycle end with release/exhaust of pressure & alarm is automatic.
  • Microprocessor based Controller with time and temperature programmable by user.
  • Timer Range: 1-99 Minutes.
  • Temperature Sensor: PT-100.
  • Low water level alarm with heater cut off.
  • Perforated basket made of Stainless-Steel sheet – 304 grades.
  • Operates on 230 Volts AC Single phase 50 Hz.

Temperature Range: 121°C to 125°C
Temperature Resolution: 0.1°C
Pressure Range: 15 PSI to 20 PSI (Factory Set at 15 PSI)

Model Number : NI-AUV
HSN CODE : 84191920

  • Triple walled in construction with Inner made of Stainless Steel – 304 Grade & Exterior of CRCA steel with powder coat finish.
  • Interior made of Stainless Steel – 316 grade and Exterior of Stainless Steel 304 grade matt finish in all GMP MODELS.
  • Food grade Silicon Rubber gasket which acts as a perfect sealant.
  • A transparent full-length Acrylic inner door is provided to have a clear inner view of the samples/specimens put in, without disturbing the Thermal Conditions inside the incubator.
  • Heating elements are made of high-grade Nichrome wire and placed at the both sides.
  • Temperature controlled by Dual Display Microprocessor based PID Temperature Controller & PT-100 sensor.
  • Air circulation by motorized blower placed on top of the incubator.
  • Available with removable S.S. Rod shelves.
  • Temperature Range: 5°C above ambient to 60°C.
  • Temperature Accuracy: ± 1°C or better.
  • Temperature Uniformity: ± 1°C or better.
  • Operates on 230 Volts AC Single phase 50 Hz.

Safety Feature: Capillary type Thermostat provided to take care of temperature overshoots & in case the PID Controlling system fails.

MODEL

WORKING SPACE (W X D X H)

CAPACITY

WATTS

SHELVES

NI-BAI-01

14” X 14” X 14” (35 X 35 X 35)

45 LTRS

300

2 NOS.

NI-BAI-02

18” X 18” X 18” (45 X 45 X 45)

90 LTRS

400

3 NOS.

NI-BAI-03

18” X 18” X 24” (45 X 45 X 60)

120 LTRS

750

3 NOS.

NI-BAI-04

24” X 24” X 24” (60 X 60 X 60)

220 LTRS

1000

3 NOS.

NI-BAI-05

24” X 18” X 36” (60 X 45 X 90)

250 LTRS

1250

3 NOS.

NI-BAI-06

24” X 24” X 36” (60 X 60 X 90)

325 LTRS

1500

4 NOS.

 

OPTIONAL ACCESSORIES:

A. Digital Timer with Temp. Controller of 999 minutes: Rs. 4000/-
B. PC/Printer Interface: RS 232 or 485 PC interface.

ELECTRIC BUNSEN BURNER

  • Electric Bunsen Burners are designed & used for evaporation of solutions in China Dish & can be used for any routine heating application in the laboratory.
  • Heating element is fixed within the conically shaped refractory cup.
  • Cup is enclosed in a stainless-steel casing and well insulated.
  • S.S. casing is mounted on a stainless-steel body with perforations to prevent temperature rise.
  • Temp. Controlled by Energy regulator.
  • Operates on 230 Volts AC Single phase 50 Hz.

NOTE :

  • IQ/OQ/PQ DOCUMENT CHARGES WILL BE EXTRA AS APPLICABLE.
  • ON SITE VALIDATION CHARGES WILL BE EXTRA AS APPLICABLE.

MODEL

RATING

MAXIMUM TEMPERATURE

NI-BNB-01

300 W

700°C

       
         
         
         
         
         
         
         
         
         

NOTE :

  • IQ/OQ/PQ DOCUMENT CHARGES WILL BE EXTRA AS APPLICABLE.
  • ON SITE VALIDATION CHARGES WILL BE EXTRA AS APPLICABLE.

Frequently Asked Questions